What are the precautions for using the barrel pump?

Intercalation pump also called oil drum pump, should be based on process, water supply and drainage requirements, from the liquid delivery volume, the device head, liquid properties, piping layout and operating conditions of operation to be considered in five areas. Easy maintenance, reliable performance, long service life, simple appearance, advanced and reasonable structure, international standards, delivery without solid particles of liquid. Drum Pump Category: Hand drum pumps, electric drum pumps, pneumatic drum pumps. What are the precautions for using the barrel pump? First, please check HD series electric pump handrail and outlet pipe is locked. Second, the impeller allows the following soft particles 3mm particles, if more than this size, please install a separate filter. Third, the pump should not be stored in humid or sour gas, hot gas and a variety of corrosive gases too heavy place. Fourth, the motor, air motor and pump is strictly prohibited collision damage. Five, HD-A series of air motor models, operation must be equipped with automatic oil-added pneumatic triple pieces (in addition to water filtration, lubrication, pressure adjustment). Note: ISO VG32 lubricating oil turbine oil (commonly known as 1 # turbine oil). Sixth, please pump the pipe and outlet pipe placed in the designated safety zone before turning on the electric (gas) source. Seven, the use of electricity (gas) source, please start small to large, in order to extend pump running time and life expectancy, but also to prevent personnel danger. Eight, pay attention to the voltage is correct. Nine, speed motor has overload protection device (other pump type recommended in the power line into the overload protection device). Ten, when using, must have the professional field operation, the personnel in the operation process must not leave the scene. Eleven, general barreled portable pump can extract the viscosity of about 800cps, high-lift impeller viscosity of up to 1000cps, for the delivery of higher viscosity liquid, please use other high-viscosity pump. 12, motor or air motor and pump pipe installation, please confirm whether the proper placement, such as improper installation, will result in motor motor coupling and pump coupling damage. Thirteen, if you find the pump has a different sound. Please check whether the inhalation of foreign objects and impeller collision. Fourteen, when conveying the liquid as the solvent, it is necessary to use explosion-proof motor or air motor, and connect the ground wire at the same time to ensure the safety on the use. 15, motor or air motor and pump tube installed before, please confirm the switch is off OFF state. Sixteen, motor or air motor Do not immerse in the liquid or splash into the liquid. Seventeen, HD series pump should be used at an altitude of 1000 meters below. Asia Fluid Network () Editor: Huang Nengwen, QQ:

Plenum Boxes

Plenum Boxes,Duct Plenum Box,Diffuser Plenum Box,Supply Air Plenum Box

Guangzhou Jointair Co., Ltd. , https://www.jointair.cn

This entry was posted in on